Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Flow Meter
Flow Meter Types
» Air Flow Meter
» Ultrasonic
» Smart Meters
» Thermal Mass
» Mass Flow Controller (MFC)
» Coriolis Mass
» Rotameter
» Positive Displacement PD Meter
» Vortex shedding
» Multiparameter Mass Vortex
» Multiphase
» Turbine
» Gas Flowmeter
» Compressed Air Meter
» Calorimetric
» Compound Meter
» Electromagnetic
» Flumes & Weirs
» Insertion Flow Meter
» Open Channel
» Orifice plate
» Paddle Meter
» Variable Area
» Venturi
» Doppler
» Transit-Time
» Portable Flow meter
» Low Flow Measurement
» Laminar Mass
» Medical
» OEM
» Differential Pressure
» HPLC Flowmeter

MAGMETERS - Electromagnetic

Electromagnetic Magnetic Flowmeter - A conductive process fluid is run through a magnetic field. As it creates an electric charge through its interaction with the field, the charge is measured to find the speed of the flow.

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

Featured Electromagnetic Flowmeter Suppliers
Handheld Ultrasonic Flowmeter

Instrumart is a leading supplier of industrial instruments located just outside Burlington, Vermont. Instrumart is the operating name for Total Temperature Instrumentation, Inc. ("TTI"). Instrumart is a global company with local roots. We are a member of the Lake Champlain Regional Chamber of Commerce and Vermont Businesses for Social Responsibility. We were recently named to Inc. Magazine's Inc. 5000 list of the fastest-growing private companies in the United States for the second year in a row. Vermont Business Magazine has named Instrumart one of the Best Places to Work in Vermont and one of Vermont's Top 5 Wholesale Businesses.
More Details>>

Electromagnetic Flowmeter
Featured Electromagnetic Flowmeter suppliers
Instrumart's Electromagnetic Flowmeter
Electromagnetic Flowmeter
The Krohne OPTIFLUX 4000 electromagnetic flow sensor / magmeter is the proven choice when selecting a flow meter. This versatile flow meter is suitable for almost all applications in all industries.
More Info>>
The Dynasonics MFX MagProbe ™ insertion magnetic flow transmitter is a cost-effective solution for accurate measurement of conductive liquid in closed conduit, pressurized-pipes without process shutdown.
More Info>>
The GF Signet 2552 magmeter flow sensor is a heavy duty, high performance electromagnetic flow sensor in an adjustable-insertion configuration. The GF Signet 2552 magmeter can be used with a ball valve for hot-tap installations.
More Info>>
The Krohne Enviromag 2000 electromagnetic flow meter is suitable for either clean, homogeneous or dirty, non-homogeneous flow applications. Configurable into a number of system designs, the Krohne Enviromag 2000 electromagnetic flow meter is is designed for use with either the Krohne IFC 010 or Krohne IFC 300 flow converters. 
More Info>>
More about Electromagnetic Flowmeters
The operating principle of magnetic flowmeters is based upon Faraday's Law of electromagnetic induction,
" It states that a voltage will be induced in a conductor moving through a magnetic field."
Faraday's Law :
E=kBDV Where
E = Induced Voltage,
B = Strength of the magentic field,
D = Conductor Width,
V = Velocity of the conductor.
The magnitude of the induced voltage E is directly proportional to the velocity of the conductor V, conductor width D, and the strength of the magnetic field B. Magnetic field coils placed on opposite sides of the pipe generate a magnetic field. As the conductive process liquid moves through the field with average velocity V, electrodes sense the induced voltage. The width of the conductor is represented by the distance between electrodes. An insulating liner prevents the signal from shorting to the pipe wall. The only variable in this application of Faraday's law is the velocity of the conductive liquid V because field strength is controlled constant and electrode spacing is fixed. Therefore, the output voltage E is directly proportional to liquid velocity, resulting in the linear output of a magnetic resulting in the linear output of a magnetic flowmeter

Magnetic Flowmeters
Magnetic flowmeters are based on Faraday's Law of Magnetic Induction. In a magnetic flowmeter, the liquid acts as a conductor as it flows through the pipe. This induces a voltage which is proportional to the average flow velocity - the faster the flow rate, the higher the voltage. This voltage is picked up by sensing electrodes mounted in the meter tube and sent to the transmitter which takes the voltage and calculates the flow rate based on the cross sectional area of the meter tube.

Where to use

  • High percentage of solids
    Sludges, slurries, minerals, paper, sewage - flows with high levels of solids which cannot be measured other types of meters.
  • Obstructionless measurement
    Nothing projects into the flow stream, no head loss, no parts to maintain.
  • Very corrosive liquids
    Acids, caustics and corrosive chemical additives are isolated from the meter by inert linings and electrodes.
  • Conductive Liquids
    Liquids where conductivity is at sufficient levels to induce measurable voltage
Flow Indication & Control
» Straighteners / Conditioners
» Static Mixers
» Vaporizer Systems
» Sight Glass Indicators
» Flow Switch
» Indicator Panels
» Watercut meters
» Sensors
» Nozzles
» Crude Oil Mixing
» Leak Detection
» Air Eliminators
» Automatic Meter Reading
» Net Oil Computer
» Water Meters
» Wind Meters
» Test and Calibration Centers
» Flow Bench
» Hydraulic Flow Switch