Article: How pipeline Doppler Flowmeters work
Submitted by: JP (Engineering Student)
Submit date:13/05/02

How pipeline Doppler Flowmeters work

The Doppler flowmeter measures the velocity of particles moving with the flowing fluid . Acoustic signals of known frequency are transmitted, reflected from particles, and are picked up by a receiver. The received signals are analyzed for frequency shifts and the resulting mean value of the frequency shifts can be directly related to the mean velocity of the particles moving with the fluid. Software can be used to reject stray signals and correct for frequency changes caused by the pipe wall or transducer protective material. Doppler flowmeter performance is highly dependent on physical properties such as the liquid's sonic conductivity, particle density, and flow profile. Likewise, nonuniformity of particle distribution in the pipe cross section results in a computed mean velocity that is incorrectly weighted. Therefore, the meter accuracy is sensitive to velocity profile variations and to distribution of acoustic reflectors in the measurement section. Unlike other acoustic flowmeters, Doppler meters are affected by changes in the liquid's sonic velocity. As a result, the meter is sensitive to changes in density and temperature. These problems make Doppler flowmeters unsuitable for highly accurate measurements in some applications. Doppler meters play a very important role where other meters will not work. These might be liquid slurrys, aerated liquids or liquids with some small or large amount on suspended solids

 

 


This article has been contributed by JP (Engineering Student)

Types of Flowmeters
» Air Flow Meter
» Ultrasonic
» Smart Meters
» Thermal Mass
» Mass Flow Controller (MFC)
» Coriolis Mass
» Rotameter
» Positive Displacement PD Meter
» Vortex shedding
» Multiparameter Mass Vortex
» Multiphase
» Turbine
» Gas Flowmeter
» Compressed Air Meter
» Calorimetric
» Compound Meter
» Electromagnetic
» Flumes & Weirs
» Insertion Flow Meter
» Open Channel
» Orifice plate
» Paddle Meter
» Variable Area
» Venturi
» Doppler
» Transit-Time
» Portable Flow meter
» Low Flow Measurement
» Laminar Mass
» Medical
» OEM
» dP cell/transmitter
» Flow Meter