Flow Meter Types |
|
|
|
|
| Vortex
Flowmeter |
An
obstruction in a pipe creates vortices on the
downstream side of the obstruction. Temperature
or pressure sensors measure the vortices to gauge
the strength of flow. |
|
| Featured Vortex
Flowmeter Suppliers |
|
Sierra's Multivariable product line features an inline version, the Model 240 Innova-Mass® vortex flowmeter and a unique immersion version, the Model 241 Innova-Mass®. The Model 241 has emerged recently as the proven instrument of choice in geothermal steam applications across the globe. The Model 240 and Model 241 can measure the mass flow rate of any gas or liquid and are ideally suited for saturated or superheated steam. The Model 241 vortex flow meter is available in high-pressure versions capable of mass flow measurement of gases up to 5000 psig. Our Multivariable Technology allows one instrument and one process connection to measure FIVE process parameters at the same time to simultaneously measure mass flow rate, temperature, pressure, volumetric flow rate, and fluid density.
More
Details>>
|
|
|
 |
|
Aalborg’s
unique dual signal processing technology independently
measures each vortex on either side of the bluff
body and filters out non-flow noise. This results
in less noise and higher accuracy throughout the
flow range.
More
>> |
|
|
 |
|
| Featured Vortex
Flowmeter Products |
| Sierra: Multivariable Mass & Volumetric Vortex Flow Meters |
 |
- Inline mass vortex flow meter
- Read five process variables with a single device
- Precisely measure any gas, liquid or steam
- Fully field-programmable
Sierra's Multivariable product line features an inline version, the Model 240 Innova-Mass® vortex flowmeter and a unique immersion version, the Model 241 Innova-Mass®. The Model 241 has emerged recently as the proven instrument of choice in geothermal steam applications across the globe.
The Model 240 and Model 241 can measure the mass flow rate of any gas or liquid and are ideally suited for saturated or superheated steam. The Model 241 vortex flow meter is available in high-pressure versions capable of mass flow measurement of gases up to 5000 psig. Our Multivariable Technology allows one instrument and one process connection to measure FIVE process parameters at the same time to simultaneously measure mass flow rate, temperature, pressure, volumetric flow rate, and fluid density.
More Info>> |
| Aalborg: Vortex Inline
Flowmeter |
|
- BENEFITS
- RELIABLE No moving parts to wear or fail.
- Electronics can be remote mounted up to 30.5
m
(100 ft).
- No fluid to sensor contact.
- No holes to clog.
- WIDE RANGEABILITY
- High flow turndown ratio up to 80:1.
- Dual signal processing technology improves
accuracy at low flows.
- HIGH ACCURACY
- 0.5% of rate.
- Increased noise cancellation as a result of
dual signal processing technology.
|
Vortices are created when
a fluid passes around a bluff body as shown below.Vortices
are alternately shed on each side of the body, 180 degrees
out of phase to each other, resulting in an oscillating
pressure gradient. As flow increases the frequency of
vortices increases in proportion to the increased flow
thereby creating a linear relationship.
AALBORG’s unique dual signal processing technology
independently measures each vortex on either side of
the bluff body and filters out non-flow noise. This
results in less noise and higher accuracy throughout
the flow range. Dual signal processing technology independently
measures each vortex providing increased accuracy and
turndown.
More Info>> |
|
 |
Flow Indication & Control |
|
|
|
|